Your browser is not supported

You are using a browser we do not support any longer. To continue visiting our website, please choose one of the following supported browsers.

Search Edwards Vacuum
Red SAFECONN Cable

You’ve trusted the Gamma SAFECONN™ high voltage cable for 30 years. Now the RED SAFECONN™ cable takes safety even further with clear high-voltage identification, low smoke zero halogen materials, and UL 1685 compliance for labs, research facilities, and universities.

Why RED SAFECONN™

·       30 years of SAFECONN interlock protection

·       Automatically shuts down high voltage when disconnected

·       0 chance of accidental 7,000V exposure

·       Proprietary Gamma design

Reliability

·       Red = high voltage (standard visual safety language in national labs)

·       Greater than 1,000V clearly indicated

·       Reduces human error risk

Save energy cost

·       Low Smoke Zero Halogen cable jacket

·       Minimizes toxic gas release in fire conditions

·       Designed for enclosed lab environments

Low Smoke Zero Halogen Icon due to minimal smoke

·       Tested and certified to UL 1685 flame exposure & smoke measurement 

·      Requested by Lawrence Berkeley National Lab

·      Meets strict institutional safety standards

EDW_Icon_Certified-Protection_2_2025

Standard vs. RED SAFECONN™

Black Cable (Standard)

Red Cable (Premium)

Trusted standard

Premium safety-forward upgrade

SAFECONN interlock

SAFECONN interlock

Traditional Silicone Rubber black jacket

Red high-voltage visual identifier

Standard insulation

Low Smoke Zero Halogen

No UL rating

UL 1685 certified

Experience Safer High‑Voltage Performance with RED SAFECONN™

Designed for ion pumps and controllers operating up to 7,000 volts, RED SAFECONN™ automatically shuts down high voltage the moment a cable is disconnected, eliminating the risk of live cable exposure. Because ion pumps have no moving parts and make no noise, there’s no visual or audible indication when energized, making interlock protection essential. The proprietary 3‑wire design uses a 5V safety circuit and a spring‑loaded detent plunger that only completes the signal when fully connected, so there’s zero chance of a live cable. With a red high‑voltage identifier, LSZH materials, and UL 1685 compliance, RED SAFECONN™ sets a new benchmark for safety in research environments.

Labratory with a high voltage danger sign on electrical panel

Ready to Request a Quote for the RED SAFECONN™ High Voltage Cable?

SERVICE SOLUTIONS

Read more on our offerings in Service Solutions