nEDC & EDC Dry Claw Vacuum Pumps - Brochure
Robust single stage dry claw vacuum pumps
The Edwards EDC500-1000 single stage dry claw vacuum pumps bring together compact design and sustainable energy-efficiency. Through their versatility, small footprint, and tough construction, they are a reliable choice for even the most demanding industrial applications. With their technological advancements and low maintenance features, the EDC dry claw vacuum pumps set to make a new standard for vacuum excellence.
The claws and rotor housing are of the EDC pumps coated with durable high temperature resistant material and is tolerant to water vapour – boosting their durability and corrosion resistance.
The design of the pumps ensures the gears chamber is separated from the pumping chamber by a labyrinth seal. This extends the life of your EDC dry claw vacuum pump.
Along with tough design, this range of dry claw vacuum pumps have an integrated bottom silencer and a connected external silencer at the exhaust for silent operations.
The dry pumping chamber is oil-free with no mechanical contact to cause excessive wear and tear. It also has an inlet check valve to prevent back contamination.
Our market-leading warranty and service support network spans 180 countries. This means you can rely on 24/7 support for your products and production processes, wherever you happen to be.
| Unit | EDC500 | EDC6000 | ||
| Performance | Peak pumping speed (50Hz) | m3h-1 / cfm | 500 / 294 | 950 / 559 |
| Peak pumping speed (60Hz) | 600 / 353 | 1140 / 671 | ||
| Ultimate vacuum continuous | mbar / torr | 200 / 150 | 200 / 150 | |
| Nominal motor power | @ 50Hz | kW / hp | 9.2 / 12.3 | 18.5 / 24.8 |
| @ 60Hz | 11 / 14.7 | 22 / 29.5 | ||
| @ RPM | 50Hz / 60Hz | 3600 / 3000 | ||
| Operating data | Noise (50Hz / 60Hz) | dB(A) | 76 / 78 | 82 / 85 |
| Operating temperature (50Hz / 60Hz) | °C / °F | 5 to 40 / 41 to 104 |
5 to 40 / 41 to 104 |
|
| Oil capacity (Gear box) | l / gal | 1.5 / 0.30 | ||
| Length | Width | Height | Inlet connection size | Outlet connection size | ||||
| mm | in | mm | in | mm | in | |||
| EDC500 - Bareshaft 50Hz | 811 | 31.9 | 586 | 23.0 | 845 | 33.2 | G3” | G2 ½” |
| EDC500 - Bareshaft 60Hz | 822 | 32.3 | 586 | 23.0 | 845 | 33.2 | G3” | G2 ½” |
| EDC1000 - Bareshaft 50Hz | 1169 | 46.0 | 680 | 26.7 | 1274 | 50.1 | DN100 PN6 | DN100 PN6 |
| EDC1000 - Bareshaft 60Hz | 1169 | 46.0 | 680 | 26.7 | 1274 | 50.1 | DN100 PN6 | DN100 PN6 |
| EDC500 - 400V 50Hz 3Ph IEC | 1250 | 49.2 | 586 | 23.0 | 845 | 33.2 | G3” | G2 ½” |
| EDC500 - 380V 60Hz 3Ph IEC | 1302 | 51.2 | 586 | 23.0 | 845 | 33.2 | G3” | G2 ½” |
| EDC500 - 460V 60Hz 3Ph IEC UL | 1302 | 51.2 | 586 | 23.0 | 845 | 33.2 | G3” | G2 ½” |
| EDC1000 - 400V 50Hz 3Ph IEC | 1468 | 57.7 | 680 | 26.7 | 1240 | 48.8 | DN100 PN6 | DN100 PN10 |
| EDC1000 - 380V 60Hz 3Ph IEC | 1424 | 56.0 | 680 | 26.7 | 1274 | 50.1 | DN100 PN6 | DN100 PN10 |
| EDC1000 - 460V 60Hz 3Ph IEC UL | 1424 | 56.0 | 680 | 26.7 | 1274 | 50.1 | DN100 PN6 | DN100 PN10 |