Edwards range of turbomolecular pumping stations has been developed to provide a comprehensive vacuum solution with the latest technological advances for easy installation and operation.
Ultimate ready to go vacuum solutions
Edwards T-Station 85 pumping station
The T-Station 85 seamlessly combines an nEXT85H turbomolecular pump with either a dry diaphragm pump or oil sealed backing pump and a simple controller, providing pumping speeds of 47 l/s to 84 l/s. The T-Station 85 comes with an integrated Turbo and Active Gauge controller which enables single button start/stop of the system, the ability to control one of our active gauges, vent valve control and delayed start of the turbomolecular pump to either time or pressure if a gauge is fitted, making the T-Station 85 ideal for general laboratory needs.
Edwards TIC turbomolecular pumping stations
All Edwards turbomolecular pumping stations come with a TIC turbo and instrument controller, enabling system start/stop from the control panel and easy integration of Edwards active gauges. TIC turbomolecular pumping stations come in a range of pumping speeds from 85 l/s up to 400 l/s, a TIC controller, and a choice of either oil-sealed or dry backing pump. All our TIC turbomolecular pumping stations come with the market leading nEXT turbomolecular pumps providing proven reliability and end-user serviceability. Oil-sealed pumps come with an EMF mist filter fitted as standard and nXDS dry scroll pumps have an isolation valve fitted between the turbo pump and backing pump as standard.
T-Station 85 | Technical Specification |
Pumping speed for N2 | |
NW40 | 47 ls-1 |
ISO/CF63 | 84 ls-1 |
Compression ratio for N2 | >1 x 1011 |
Backing pump speed @50 Hz | |
E2M1.5 (TS85H Wet) | 1.6 m3h-1 |
XDD1 (TS85H Dry) | 1.2 m3h-1 |
Ultimate vacuum | <5 x 10-10 mbar* |
Inlet flange | NW40, ISO63 or CF63 |
Exhaust flange | |
E2M1.5 (TS85H Wet) | 11 mm OD nozzle or 3/8” BSP |
XDD1 (TS85H Dry) | Fitted silencer or 1/8” BSP |
Mass | |
E2M1.5 system (TS85H Wet) | 21 kg max |
XDD1 system (TS85H Dry) | 17 kg max |
Noise level | ≤56 dB(A) |
Leak tightness | <1 x 10-6 mbar ls-1 |
Operating temperature range | 12 to 40 °C |
*T-Station 85H Wet CF63 |
T-Station 85 | Technical Specification |
Pumping speed for N2 | |
NW40 | 47 ls-1 |
ISO/CF63 | 84 ls-1 |
Compression ratio for N2 | >1 x 1011 |
Backing pump speed @50 Hz | |
E2M1.5 (TS85H Wet) | 1.6 m3h-1 |
XDD1 (TS85H Dry) | 1.2 m3h-1 |
Ultimate vacuum | <5 x 10-10 mbar* |
Inlet flange | NW40, ISO63 or CF63 |
Exhaust flange | |
E2M1.5 (TS85H Wet) | 11 mm OD nozzle or 3/8” BSP |
XDD1 (TS85H Dry) | Fitted silencer or 1/8” BSP |
Mass | |
E2M1.5 system (TS85H Wet) | 21 kg max |
XDD1 system (TS85H Dry) | 17 kg max |
Noise level | ≤56 dB(A) |
Leak tightness | <1 x 10-6 mbar ls-1 |
Operating temperature range | 12 to 40 °C |
*T-Station 85H Wet CF63 |