EDC High Capacity Dry Claw

Robust single stage dry claw vacuum pumps

EDC1000

Innovative dry claw vacuum technology

The Edwards EDC500-1000 single stage dry claw vacuum pumps bring together compact design and sustainable energy-efficiency. Through their versatility, small footprint, and tough construction, they are a reliable choice for even the most demanding industrial applications. With their technological advancements and low maintenance features, the EDC dry claw vacuum pumps set to make a new standard for vacuum excellence. 

Features of the EDC500-1000 dry claw vacuum pump

  • Durable design

The claws and rotor housing are of the EDC pumps coated with durable high temperature resistant material and is tolerant to water vapour – boosting their durability and corrosion resistance. 

 

  • High longevity 

The design of the pumps ensures the gears chamber is separated from the pumping chamber by a labyrinth seal. This extends the life of your EDC dry claw vacuum pump. 

  • Strong and silent 

Along with tough design, this range of dry claw vacuum pumps have an integrated bottom silencer and a connected external silencer at the exhaust for silent operations. 

 

  • Cleaner operations 

The dry pumping chamber is oil-free with no mechanical contact to cause excessive wear and tear.  It also has an inlet check valve to prevent back contamination. 

 

  • Unmatched global service support

Our market-leading warranty and service support network spans 180 countries. This means you can rely on 24/7 support for your products and production processes, wherever you happen to be.

  • House vacuum systems
  • Plastic extrusion
  • Wood working
  • Vacuum conveying
  • Pick and place
  • Drying and degassing
  • Printing and paper converting
  • Medical systems
  • Dairy industry for milking and milk transfer
  • Thermoforming
  • Waste removal
    Unit EDC500 EDC6000
Performance Peak pumping speed (50Hz) m3h-1 / cfm 500 / 294 950 / 559
Peak pumping speed (60Hz) 600 / 353 1140 / 671
Ultimate vacuum continuous mbar / torr 200 / 150 200 / 150
Nominal motor power @ 50Hz kW / hp 9.2 / 12.3 18.5 / 24.8
@ 60Hz 11 / 14.7 22 / 29.5
@ RPM 50Hz / 60Hz 3600 / 3000
Operating data Noise (50Hz / 60Hz) dB(A) 76 / 78 82 / 85
Operating temperature (50Hz / 60Hz) °C / °F

5 to 40 /

41 to 104

5 to 40 /

41 to 104

Oil capacity (Gear box) l / gal 1.5 / 0.30
Pumping speed based on air at 20°C / 70°F. Tolerance +/-10%.
  Length Width Height Inlet connection size Outlet connection size
mm in mm in mm in
EDC500 - Bareshaft 50Hz 811 31.9 586 23.0 845 33.2 G3” G2 ½”
EDC500 - Bareshaft 60Hz 822 32.3 586 23.0 845 33.2 G3” G2 ½”
EDC1000 - Bareshaft 50Hz 1169 46.0 680 26.7 1274 50.1 DN100 PN6 DN100 PN6
EDC1000 - Bareshaft 60Hz 1169 46.0 680 26.7 1274 50.1 DN100 PN6 DN100 PN6
EDC500 - 400V 50Hz 3Ph IEC 1250 49.2 586 23.0 845 33.2 G3” G2 ½”
EDC500 - 380V 60Hz 3Ph IEC 1302 51.2 586 23.0 845 33.2 G3” G2 ½”
EDC500 - 460V 60Hz 3Ph IEC UL 1302 51.2 586 23.0 845 33.2 G3” G2 ½”
EDC1000 - 400V 50Hz 3Ph IEC 1468 57.7 680 26.7 1240 48.8 DN100 PN6 DN100 PN10
EDC1000 - 380V 60Hz 3Ph IEC 1424 56.0 680 26.7 1274 50.1 DN100 PN6 DN100 PN10
EDC1000 - 460V 60Hz 3Ph IEC UL 1424 56.0 680 26.7 1274 50.1 DN100 PN6 DN100 PN10
NPT adapters available on 60Hz USA specification machines.
nEDC & EDC Dry Claw Vacuum Pumps - Brochure

PDF

5.9 MB

SERVICE SOLUTIONS

Eliminate Unplanned Downtime. Maximize Efficiency. Minimize Costs — Stay Ahead with ServicePlan™